Subtle side wall venting keeps the system out of sight by eliminating unsightly pvc pipe running on the homes exterior.
Can radon be vented through a wall.
Called radon vact tm the proprietary system consists of a plug in fan exterior hood and installer purchased pvc pipe.
Because the radon vac side wall system evacuates through the basement side wall homeowners can avoid having pvc pipe run vertically through living areas or outside of their homes to the.
It follows the same clearances as high efficiency gas fired heating appliances that also vent through side walls they are allowed to at least 4 feet directly below a window opening.
If the fan was not operating sewer gasses could fall down the radon vent and settle under the house.
If a roof penetration is impossible you can route the radon vent through the wall or rim joist and continue the riser up the outside of the building.
It means opening up walls and messing up painted drywall.
Running the wires for a fan might mean fishing wire through a wall.
You have to cut through an already finished roof and make sure you get the vent flashed properly.
Using a sewer vent for your radon vent could be explosive and smelly.
Undoubtedly the radon problem was aggravated by the need to dig a very deep foundation wall 14 feet below grade at one corner in order to reach solid soil below fill material.
Saves this radon vac radon fan saves hundreds of dollars in extra materials and labor over a typical radon mitigation systems.
This is a serious plumbing code violation and safety issue.
Can i just tap into my sewer vent pipe.
Ideally for a roof vented system the fan should be mounted in the attic space.
Because this system is power vented by a continuously running fan it can be vented through a suitable location on the roof or at a location along the exterior wall system provided the exit port is 10 feet away from any window or door and 2 feet above.
Because the radon vact tm side wall system evacuates through the basement side wall homeowners can avoid having pvc pipe run vertically through living areas or outside of their homes to the roof line.
Epa s radon mitigation standards require vent discharge points to be above the roofline and no less than 10 feet sideways or 2 feet above any windows or vents.
Ideally a radon vent especially a passive radon vent should penetrate the roof not a wall or rim joist.
If you don t do it and the house tests high for radon it becomes much more difficult and expensive.
One of our competitor s incorrectly constructed systems.
The vent pipe discharge point is under the overhang and approximately 3 feet from the window.
Efficient motor operates quietly.
Keeping the vent pipe indoors keeps it warmer enhancing the stack effect.